A.Wall Mounting
A-1. Pull out the wire through the wiring hole on the mounting plate
and attach the plate to the wall with the screw ( 1/6x 3/4)
A-2. Connect wire to the terminals.
A-3. After checking optical alignment and operation check, ( please see
7.ALIGNMENT AND OPERATION ) replace the cover, and fasten the
cover lock screw tightly.
B.Pole Mounting
B-1. Unit mounts to a 1.66"-1.75" O.D. Pole.
B-2. Drill a 1/4" hole through pole where the beam will be mounted
for wiring.
B-3. Place U-Shape brackets at the pole.
B-4. Pull out the wire through the wire through the wiring hole of the mounting
plate, attached the mounting plate to the U-Shape bracket with screw.
B-5. Connect the wire to the terminals.
B-6. Checking optical alignment and operation check.(Please see
7.ALIGNMENT AND OPERATION)
B-7. Replace the cover, and fasten the cover lock screw tightly.
C. Two units installation (back to back)
Fix two U-Shape brackets in layers on a pole, two units can be installed
back to back on a pole at the same height.
1 2
TR. RE. RE. TR.
TR. RE.
1
2
+
_
1 2 3 4
1 2 1 2 3 4 1 2 1 23 4
1 2 1 2 3 4 1 2 1 23 4
TR. RE.
RE.
TR.
AWG22 (0.65mm)
AWG20 (0.8mm)
AWG18 (1.0mm)
AWG17 (1.1mm)
2PH-100BS/BQ 2PH-150BS/BQ
24VDC24VDC 12VDC12VDC
630
(190m)
'
5600
( 1700m )
' 490
( 150m )
'
4200
( 1280m )
'
1000
( 300m )
'
9300
( 2800m )
' 830
( 250m )
' 7200
( 2200m )
'
1600
( 480m )
'
14600
( 4400m )
'
1200
( 360m )
' 10500
( 3200m )
'
2000
( 600m )
'
18300
( 5500m )
' 1450
( 440m )
' 13500
( 4000m )
'
1 2
3
4
5
6
7
COM
NC.
NO.
NC.
+
_
The units can be mounted easily on a pole or flat surface.
Remove cover via screw at base of cover. And loosen the unit base
mounting screw and remove mounting plate by sliding it down against
the unit base.
3.WIRING
4.INSTALLATIONS
Connection Sample 1
Connection Sample 2
Connection Sample 3
Control panel
Control panel
Control panel
}
}
}
Power
Alarm (1ch.)
Alarm (2ch.)
}
}
Power
Alarm
Signal
}
}
Power
Alarm
Signal
Connection
NOTE:
1. When two or more connections is required, maximum wiring
distance is the value above divided by the number of sets.
2. The power wires could not exceed the above mentioned lengths.
Transmitter
Receiver
Wiring Distance
Wire si ze
Voltage
Model
Power
10.5V to 30VDC (non-polarity)
Power
10.5V to 30VDC
(non-polarity)
Alarm output
Dry connect relay
output NC./NO.
28VDC / 0.2A
Tamper output
Dry connect Micro SW.
Output NC.
28VDC / 0.2A